[email protected] | 50 Guohuai Road, Henan Province, China
We are a comprehensive steel machining service platform!
Home / ASTM Steel / distal radius dorsal radiocarpal locking plates

distal radius dorsal radiocarpal locking plates

distal radius dorsal radiocarpal locking plates price, Distal Radius Dorsal Radiocarpal Locking plat… acumed.netDorsal Distal Radius Plate Acumedpdfslide.netVariAx Distal Radius Locking Plate System Single volar locking plating for the intra- and extra ...In vitro, biomechanical studies have testified the stability of volar locking plate in extra-articular distal ra...

E-mail: [email protected]

GET THE PRICESEND MESSGAE

10 mins Role of a spanning plate as an internal fixator in complex distal radius dorsal radiocarpal locking plates

A removable wrist splint is worn during 2 weeks. Weight bearing through the injured wrist is immediately allowed. Removal of the spanning plate is scheduled at 3 months after radiographic evidence of fracture consolidation. In total, twelve distal radius fractures were treated by dorsal spanning plate fixation between January 2018 and January .Distal Radius Dorsal Radiocarpal Locking plat acumed.netDorsal Distal Radius Plate Acumedpdfslide.netVariAx Distal Radius Locking Plate System Cited by 8 Publish Year 2017 Author Yoshihiro Abe, Susumu Tokunaga, Takuro Moriya (PDF) Plating Versus External Fixation of Displaced Distal distal radius dorsal radiocarpal locking platesThe addition of K-wires reduces the distraction forces required for the Shortening of the distal radius greater than 2.5mm or a dorsal tilt external fixator to maintain the reduction.8 K-wires may also be used greater than ten degrees significantly increases the axial loading in conjunction with a volar buttress plate when there is a sagittal distal radius dorsal radiocarpal locking plates

Cited by 5 Publish Year Author Xiaofei Yu, Yadong Yu, Xinzhong Shao, Yanbin Bai, Tong Zhou 8 mins Comparative study between fixed-angle and polyaxial screws distal radius dorsal radiocarpal locking plates

The inclusion criteria were age over 18 years old; fresh closed distal radius fractures (less than 1 week); post-reduction radial tilt < 15°, post-reduction radial shortening > 5 mm, post-reduction dorsal tilt > 10° or volar tilt > 20° and or post-reduction intraarticular step-off > 2 mm , ; volar locking plate as definitive treatment.Cited by 4 Publish Year Author Frank J P Beeres, Rémy Liechti, Björn-Christian Link, Reto Babst distal radius dorsal radiocarpal lockin dorsal radiocarpal ligament dorsal radiocarpal lig Cited by 21 Publish Year 2013 Author Yukichi Zenke, Akinori Sakai, Toshihisa Oshige, Shiro Moritani, Kunitaka Menuki, Yoshiaki Yamanaka, distal radius dorsal radiocarpal locking plates APTUS&Wrist - medartisAPTUS&Wrist . The wrist is a multi-articular joint. It consists of the carpus, distal ulna and distal radius . Fractures of the distal radius are the most common fractures in the human body. In recent years, great changes have taken place both in the treatment options of the distal radius and the patient demands which have increased.

Cited by 125 Publish Year 2011 Author Junichi Miyake, Tsuyoshi Murase, Hisao Moritomo, Kazuomi Sugamoto, Hideki Yoshikawa 8 mins Bridge Plating of Distal Radius Fractures Clinical Gate

Distal radius fractures represent one sixth of all fractures seen and treated in emergency departments. 1 The treatment goals for the management of these fractures include restoring congruity to the radiocarpal and distal radioulnar joint (DRUJ) surfaces and maintaining radial length. Currently, there are a number of established surgical options for displaced distal Cited by 1 Publish Year Author Shingo Abe, Toshiki Shimada, Tsuyoshi Murase, Kohji Kuriyama Extensor pollicis longus tendon ruptures after the use of distal radius dorsal radiocarpal locking platesCurrently, volar locking plates are commonly used to treat distal radius fractures (DRF) because of their stable biomechanical construct and because they cause less soft tissue disturbance and allow early mobilisation of the wrist . Complications such as rupture of tendons have been reported to occur with use of volar locking plates .Author Xue-yang Gui, Zhao-hui Cheng, Hong-fei Shi, Yi-xin Chen, Jin Xiong, Jun-fei Wang, Xu-sheng Qiu, Zi-t distal radius dorsal radiocarpal locking plates Publish Year Management of Intra-Articular Distal Radius Fractures distal radius dorsal radiocarpal locking platesConclusions The treatment of displaced intra-articular distal radius fractures with a dorsally versus a volarly placed interlocking plate system demonstrated similar clinical results. Postoperative complications were not readily observed in

Author Xue-yang Gui, Zhao-hui Cheng, Hong-fei Shi, Yi-xin Chen, Jin Xiong, Jun-fei Wang, Xu-sheng Qiu, Zi-t distal radius dorsal radiocarpal locking plates Publish Year Compari of the Orientation Angles of Volar Locking distal radius dorsal radiocarpal locking plates

The intra-articular dorsoulnar fragment of a DRF, the die-punch fragment, is reportedly difficult to fix using a locking screw from the volar side because the screw position on the dorsoulnar aspect of the distal radius is defined by the plate s position. 9, 10 Although a dorsal approach is an alternative method to fix the dorsoulnar fragment distal radius dorsal radiocarpal locking platesAuthor Álvaro Toro-Aguilera, Pablo Martínez-Galarza, Pilar Camacho-Carrasco, Miguel Caballero, Josep M. Seg distal radius dorsal radiocarpal locking plates Publish Year Distal Radius Osteotomy with Volar Locking Plates Based on distal radius dorsal radiocarpal locking platesWe retrospectively reviewed 10 consecutive patients with symptomatic distal radius malunions. Between February 2008 and November 2009, these 10 patients (all women) were treated with 3-D corrective osteotomy with volar locking plates using a custom-made surgical guide based on computer simulation (Table 1).Minimum followup was 7 months Volar locking plate versus external fixation with optional distal radius dorsal radiocarpal locking platesChou YC, et al. Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures. J Hand Surg Am. 2011;36(6):97481. Article Google Scholar 16. Earp BE, Foster B, Blazar PE. The use of a single volar locking plate for AO C3-type distal radius fractures.

The Role of Wrist Arthroscopy in Distal Radius Fractures distal radius dorsal radiocarpal locking plates

Volar locking plates have given us improved extra-articular accuracy in managing distal radius fractures in the 21st century. However, intra-articular accuracy needs to be improved. Pinning of intra-articular fragments with fluoroscopic assistance has been shown to give acceptable reduction (stepoff less than 1 mm) in only 33% of cases. Single volar locking plating for the intra- and extra distal radius dorsal radiocarpal locking platesVolar locking plating remains a popular method for the surgical management of distal radius fractures. Dorsal metaphyseal comminution (DMC) is a common fracture pattern which weakens the stability during fracture fixation. In this study, we aimed to compare the radiographic and functional outcome of the intra- and extra-articular distal radius fractures Single volar locking plating for the intra- and extra distal radius dorsal radiocarpal locking platesIn vitro, biomechanical studies have testified the stability of volar locking plate in extra-articular distal radius fracture models with DMC, and an equivalent or slightly less stability [4, 11] can be provide compared with dorsal plating. However, the efficacy of single volar locking plating in the intra-articular distal radius fracture with distal radius dorsal radiocarpal locking plates

Hand compression plate - Contours VPS-3 - Orthofix distal radius dorsal radiocarpal locking plates

The Contours VPS®-3 (Volar Plating System) is an anatomically contoured, delta-shaped plate intended for volar applications to the distal radius . The benefits to utilizing a volar approach for fixation of distal radius fractures and osteotomies are that the dorsal tissues are preserved and it may reduce the chances of tendon ruptures occurring. Distal Radius Osteotomy with Volar Locking Plates Based on distal radius dorsal radiocarpal locking platesIntroduction. Malunion is a common complication occurring in distal radius fractures treated by closed reduction and cast immobilization [4, 7].A considerable number of patients with malunions complain of wrist pain, restricted ROM in the wrist , reduced grip strength, unsightly appearance, and/or late neuropathy [6, 10, 14, 25].Corrective osteotomy that restores anatomic Distal Radius Fracture Combination of Volar Plating distal radius dorsal radiocarpal locking platesWe present the case of a 26-year-old male laborer, who sustained a high-energy, intra-articular distal radius and ulna styloid fracture. He developed subsidence and loss of fixation after index open reduction and internal fixation with a volar locking plate construct and was referred for revision surgery. Given a history of new onset seizure disorder and disuse osteopenia 6 weeks

DePuy Synthes Wrist Spanning Plate - MEDcraze

DePuy Synthes Wrist Spanning Plate . The Wrist Spanning Plate is designed for distal radius fractures with severe comminution requiring prolonged fixation, as an alternative to external fixation. Applied to the dorsal aspect of the wrist , the plate restores length and neutralizes loads on the consolidating fracture fragments.

Contact Us

With a technical production and processing team, we will supply deep service for steel plates/pipes/coils. Please leave a message about you requirement. Our professional after-sales pernel will response you in 24 hours.

  • E-mail:[email protected]
  • Tel: 0086-13569929107
  • Address: 50 Guohuai Road, Henan Province, China

Get in Touch